This site uses cookies to offer you a better browsing experience. By continuing to navigate through this site or by clicking Approve, you consent to the use of cookies on your device as described in our privacy notice.
Crimr-lite ML2 with Cam
Crimr-lite ML2 with Cam

Crimr-lite ML2 with Cam

BENCH TOP MAGNIFIER WITH MULTI-WAVELENGTH ILLUMINATION INFRARED ILLUMINATION MODULE NOW AVAILABLE

The new Crime-lite ML2 forensic light source combines the versatility of multi-wavelength, high intensity LED illumination with wide area bi-ocular magnification. An ideal system for the examination and 'marking up' of large items of evidence in the laboratory.

The Crime-lite ML2 features 8 high intensity white LEDs for general search and a choice of up to 4 additional narrowband LEDs including: UV, Violet, Blue, Blue/Green, Green, Orange & Infrared - wavelengths that are effective in detecting body fluids, semen, bone and tooth fragments, fibres, drugs, explosives, accelerants and chemically treated evidence.

Optional accessories for the Crime-lite ML2 system include an IR sensitive camera and tablet PC with image capture software for the visualization and recording of evidence undergoing infrared examination.

Enquiry

Crime-lite ML2 Applications

White light applications:

Blood spatter | Bruising and bite marks | Shoeprints | General search


UV light applications:

Bruising and bite marks | Body fluids | Fibres | Drug residues | Fingerprint treatments including Ardrox and Nanoparticles


Violet light applications:

Blood spatter | Bruising and bite marks | Body fluids | Hair | Fibres | Drug residues | Fingerprint treatments including Basic Yellow


Blue light applications:

Blood spatter | Body fluids | Bone & tooth | Hair | Fibres | Gunshot residues | Accelerants | Fingerprint treatments including Redwop, Basic Yellow, Acid Yellow, Ardrox and Magnetic powder


Blue/Green light applications:

Bone & tooth | Fibres | Gunshot residues | Accelerants | Fingerprint treatments including Redwop, Greenwop, DFO, and Rhodamine 6G


Green light applications:

Bone & tooth | Fibres | Accelerants | Fingerprint treatments including Nanoparticles, DFO and Ninhydrin


Orange and Red light applications:

Fibers | General contrast search | Fingerprint treatments including DFO


Infrared light applications:

Blood spatter | Fibres | Gunshot Residues | Inks

Crime-lite ML2 Specifications

Features & Specifications
  • 8 x high-efficiency White LEDs
  • Your choice of additional narrowband LED modules
  • large 3.5 dioptre magnifying lens
  • Optimised for the laboratory examination of large items
  • Heavy duty bench or wall mounted arm
  • Three-axis adjustable head mount
  • Air filter to maintain a clean environment
  • 100-240V AC power input
  • Power saving mode
  • Optional Vis/IR Camera Module

Available Wavelengths

White LED's fitted as standard plus your choice of narrowband LED modules.
For information on available configurations please download the product brochure or contact our sale team

 

White
400-700nm

 

UV
350-380nm

 

Violet
400-430nm

  Blue
420-470nm
 

Blue/Green
450-510nm

  Green
480-560nm
  Orange
570-610nm
  Red
610-660nm
  Infrared
800-900nm

Crime-lite ML2 Accessories

Bandpass Viewing Filters

In addition to the standard filters supplied with the Crime-lite ML2, a selection of Bandpass Viewing Filters, tailored for the examination of specific evidence types, are also available.
  • 415nm for the visualization of blood spatter
  • 530nm for the visualization of body fluids
  • 550nm for the visualization of body fluids

Each Bandpass Viewing Filter is manufactured from Schott glass with an additional coating to suppress auto-fluorescent emissions from the Schott glass itself, thus ensuring maximum optical performance when using high power light sources.

 

Crime-lite ML2 Infrared Accessories

Evidence undergoing infrared examination using the Crime-lite ML2 IR module is visualized using an IR sensitive camera attachment with live video images being displayed on a PC monitor.

5MP IR sensitive camera

For the visualization and digital image capture of evidence

  • Attaches to the Crime-lite ML2
  • Rotates into position over the viewing lens
  • Hi-speed USB 2.0 interface
  • Includes UV, Vis & IR filters
  • Includes image capture software

Tablet PC Mount

Adjustable mount that clamps tablet PC to Articulated Arm

Laboratory Cart

Available for use with all Foster + Freeman Crime-lites, this robust wheeled cart is ideal for use in forensic laboratories.

The 70x60x70cm unit is mounted on lockable castors and can be manoeuvred around exhibits. A two-point fixing plate allows for the easy attachment of a Crime-lite articulated arm.

An optional uninterruptible power supply can be used to power equipment with no trailing wires. When not in use the trolley can be connected to an AC mains power outlet to be recharged.

Features Include:

  • Optimised for the examination of large items in the laboratory
  • Choice of White, UV, Violet, Blue, Blue/Green, Green, Orange & IR
  • Supplied with fluorescence viewing filters matching the selected LEDs
  • Large bi-ocular lens providing nominal magnification of x 1.8
  • Optional 5MP Vis-IR camera for use with IR illumination

Technical Resources

Bench top magnifier with multi-wavelength illumination for general search and fluorescence examinations

Crimr-lite ML2 with Cam

VIEW

Contact Us at +9714 2152799

We can help you with a solution tailor to your specific need.